New Product badge_Umy Medical
Genuine Trusted badge_Umy Medical
Best Offer badge_Umy Medical

Touch-Enabled Digital Electrocardiograph | Multi-Channel Resting ECG Machine with Z-Fold Thermal Printer, Simplified Hygienic Keypad, & Auto-Interpretation for Modern Clinics

SKU: UMH-5512G
Brand: Umy
MOQ: 1
Origin: China

Modernize your cardiovascular triage with a sleek, easy-to-clean electrocardiograph that combines the convenience of touch operation with the professional output of Z-fold thermal printing.

In today’s fast-paced clinical settings, bulky physical keyboards can slow down workflow and harbor dangerous pathogens. This advanced digital ECG machine embraces a minimalist, hygienic design philosophy. By shifting complex navigation and patient data entry to an intuitive on-screen virtual keyboard, the physical console is reduced to only the most essential, fully sealed quick-access buttons. This allows clinical staff to completely sanitize the device in seconds.

Quick Info.

Engineered for modern healthcare environments that prioritize digital workflows and strict infection control, this advanced multi-channel digital electrocardiograph delivers precision cardiac diagnostics without the clutter of traditional keyboards. By utilizing a responsive color display for virtual patient data entry and a simplified, fully sealed membrane control panel, it ensures effortless sanitization and streamlined operation. Equipped with a high-resolution thermal array printer optimized for Z-fold paper, it produces flat, professional-grade ECG traces that are ideal for immediate cardiologist review and long-term physical archiving.

The Specific Parameters

TECHNICAL SPECIFICATION

 (Technical Parameter)  (Specification) (Technical Parameter) (Specification)
Lead

Standard 12 leads

Frequency response0.05 ~ 160Hz(-3db) 0.05 ~ 160Hz(-3db)
Lead acquisition

32000Hz, 12 leads synchronously acquisition

Inter-channel interference

≤0.5mm

Work mode

Manual / Auto / R-R / Store.

Noise level

<15uVp-p

Filter

AC / EMG / Anti-Drift Filter

Sensitivity

$5, 10, 20, 40, Auto (mm/mV)$

CMRR

≥120dB (with AC filter)

Recording mode

3chx4+R, 6chx2, 6chx2+R,12chx1

Input circuit

Floating; Protection circuit against defibrillator effect

Paper speed

6.25, 12.5, 25, 50mm/s (±3%)

Input impedance

≥2.5MQ2 (10Hz)

Recording paper

210mmx30m, thermal roll paper

Input circuit current

≤0.05uA

Display

9 inch color LCD

Patient current leakage

< 10uA

Internal memory

400 patient cases storage

Calibrating voltage

1mV±2%

Communication port

USB, UART

Voltage tolerance

≥±500mV

Power supply

AC: 75-265V(±10%), 50/60Hz, 60VA

DC: Lithium battery 14.4V, 4400mAh

Time constant

>3.2s

Dimension/Weight

310mmx278mmx76mm/3.0Kg

PRODUCT FEATURES

Sampling and Analysis
* Acquisition and record standard 12 lead ECG simultaneously. Sampling rate 32000 Hz.
* High accuracy digital AC filter, EMG filter and base line anti-drift filter. Automatic base line adjustment.
* Accurate pulse pace identification function.
* Excellent auto-interpretation function can identify and analyze over 200 kinds of abnormal ECG. (Analysis data base: Minnesota Code).

Record
* High resolution thermal printing system.
* Four working modes: Auto, Manual, R-R, Store. to meet different clinical requirements.
* Recording format: 3chx4+3R, 6chx2, 6chx2+R, 12chx1 and 1 minute rhythm lead record.
* Printing paper size: 210mm x 30m, roll paper or 210mm x 140mm z-fold paper.

Patient Information and File Management
* With big touch screen, very easy to input and edit patient information.
* Can record detailed patient information, including name, ID, age, gender, height, weight, systolic/diastolic blood pressure and hospital name.
* Can store, replay and edit 400 ECG cases with internal memory card.
* Support external USB drive storage.

Display and Keypad
* 800 x 480 graphic, 9-inch color LCD to display detailed ECG waveform and working status. (Display ECG waveform, patient information, sensitivity, paper speed, filter, date and time, heart rate, battery status, paper status, error message and etc.)
* Soft silicon keyboard and touch screen to operate and input information.
* One-key operation to support fast ECG examination.

Power Supply
* Rechargeable built-in Lithium battery, 4400mAh, 14.4V, support to continuously work about 18 hours.
* Low-power consumption and fast charging design, about 4.5 hours to charge full.
* Adapt for power supply of 110-230V, 50/60Hz. Automatic switching between battery and AC power supply.

Appearance Design
* Compact and ergonomic design, easy to carry and operate.
* Small size and light weight, very convenient for mobile diagnostics.
* Measurement: 310mm x 278mm x 76mm, 3.0kgs.

Communication and Optional Function
* With UART (RS232) and USB communication port.
* Support transferring ECG files to external USB drive for storage or to laser printer to print ECG report on normal A4 paper.
* Support connecting to bar-code scanner to scan patient code.
* Support connecting to PC for real-time data transmission and data upload (optional).

TECHNICAL SPECIFICATION
– Lead: Standard 12 leads
– Lead acquisition: 32000Hz, 12 leads synchronously acquisition
– Work mode: Manual / Auto / R-R / Store.
– Filter: AC / EMG / Anti-Drift Filter
– CMRR: >= 120dB ( with AC filter )
– Input circuit: Floating; Protection circuit against defibrillator effect
– Input impedance: >= 2.5Mohm (10Hz)
– Input circuit current: <= 0.05uA
– Patient current leakage: < 10uA
– Calibrating voltage: 1mV +/- 2%
– Voltage tolerance: >= +/- 500mV
– Time constant: >= 3.2s
– Frequency response: 0.05 – 160Hz (-3db)
– Inter-channel interference: <= 0.5mm
– Noise level: < 15uVp-p
– Sensitivity: 5, 10, 20, 40, Auto (mm/mV)
– Recording mode: 3chx4+R, 6chx2, 6chx2+R, 12chx1
– Paper speed: 6.25, 12.5, 25, 50mm/s (+/- 3%)
– Recording paper: 210mm x 30m, thermal roll paper
– Display: 9 inch color LCD
– Internal memory: 400 patient cases storage
– Communication port: USB, UART
– Power supply: AC: 75-265V (+/- 10%), 50/60Hz, 60VA; DC: Lithium battery 14.4V, 4400mAh
– Dimension/Weight: 310mm x 278mm x 76mm / 3.0Kg

Strategic Advantages for Healthcare Procurement & Distribution:

  • The Z-Fold Printing Advantage: Traditional roll paper often curls, making it frustrating for cardiologists to measure intervals with calipers and difficult for medical records staff to scan. This system’s dedicated Z-fold printing mechanism outputs flat, neatly paginated reports that lay perfectly on a desk or seamlessly fit into physical patient files.

  • Reduced Training Time: The smartphone-like intuitive interface reduces the learning curve for new nursing staff. Operators can input demographics, preview live multi-channel waveforms to ensure signal stability, and execute a print command with minimal training.

  • Future-Proof Digital Transition: While it excels at physical printing, it is equally adept at paperless operations. It acts as a digital diagnostic hub, capable of transmitting precise ECG data directly to your hospital’s Electronic Medical Records (EMR) system, cutting consumable costs over the device’s lifespan.

Crucial B2B Sourcing Q&A

Q1: Why does this ECG machine use Z-fold paper instead of standard thermal roll paper?

A: Z-fold paper is the preferred choice for professional cardiologists. Unlike roll paper, which curls up and is difficult to handle, Z-fold paper stacks neatly as it prints and lays completely flat on a desk. This makes manual caliper measurements easier and simplifies the process of scanning or filing the report into physical patient folders.

Q2: Without a full QWERTY keyboard, how do nurses enter patient information?

A: The device features a large, high-resolution color screen that operates with an intuitive virtual keyboard (similar to a tablet). This allows for rapid and accurate entry of patient ID, age, and gender directly on the screen, keeping the physical control panel uncluttered and hygienic.

Q3: How does the simplified keypad design improve hospital infection control?

A: Standard physical keyboards have deep crevices between the keys where dust, fluids, and bacteria can accumulate. This device features a completely flat, sealed membrane panel with only a few essential buttons. Medical staff can wipe down the entire surface with hospital-grade disinfectants quickly and safely, drastically reducing the risk of cross-contamination.

Q4: What OEM customization services do you offer for international medical distributors?

A: We provide comprehensive OEM and ODM solutions. This includes custom branding on the device housing, localization of the software interface and diagnostic algorithm into multiple languages, tailored connectivity protocols to match regional EMR standards, and complete CE/ISO documentation to guarantee smooth customs clearance and regulatory approval.

OR

Scroll to Top