New Product badge_Umy Medical
Genuine Trusted badge_Umy Medical
Best Offer badge_Umy Medical

300W High-Frequency Electrosurgical Generator with Precision Fabrication

SKU: UMY-VEHE-001
Brand: Umy
MOQ: 1
Origin: China

OR

Quick Info.

Power Source: Electric
Warranty: 1 Year
After-sale Service: Online technical support
Material: Metal, Plastic, Medical Stainless Steel
Instrument Classification: Class II
Safety Standard: GB9706.1-2007

This 300W high-frequency electrosurgical generator is expertly fabricated for precision and efficiency in surgical applications. Designed for versatile use, it provides superior cutting and coagulation capabilities with minimal tissue damage. Ideal for general, plastic, and laparoscopic surgeries, this device ensures safety and reliability in clinical settings. Its robust construction and advanced technology make it a dependable solution for hospitals and surgical centers worldwide.

The Specific Parameters

ITEMSPARAMETERS
Working Mode
Monopolar Cut1W~300W
Blend 11W~250W
Blend 21W~150W
Monopolar Coag1W~120W
Bipolar Coag1W~50W
Electrical Requirement
Operating Voltage220V±22V
Monopolar Rate Load300Ω
Max Input Current1400VA
Measuring Frequency530KHz±2
Bipolar Rate Load100Ω
Environmental Conditions for Use
Temperature10°C to 40°C
Relative Humidity30% to 75%
Pressure700 hPa to 1060 hPa
Environmental Conditions for Transport and Storage
Temperature-40°C to 55°C
Relative Humidity 93% non-condensing
Pressure500 hPa to 1060 hPa
Dimension (L×W×H)350mm×320mm×100mm
Weight15kg

– Maximum output power: 300W
– Five output modes: (1) pure cut, (2) mixed cut 1, (3) mixed cut 2, (4) electrocoagulation, (5) bipolar condensate;
– Electric cut mode: pure cut 100% cut, mixed cut 1 70 % cut, 30% coagulation; mixed cut 2 50 % cut, 50% coagulation;
– Pure cut: Maximum output power 300W, enabling easy surgery on any tissues and structures;
– Mixed cut: Applicable for any tissue, good coagulation effect when conducting cutting;
– Electrocoagulation: Applicable for general open surgery and fine surgical point coagulation, featuring deep tissue coagulation layer and excellent coagulation effect;

– Bipolar coagulation: When the tissues achieve the effect of coagulation, the output power will begin to reduce slowly to achieve good coagulation effect;
– Panel operation: Overall microcomputer automatic control, two-zone (LED) digital display, key function/power, switch/settings, waterproof panel design
– Automatic adjustment: Automatically fine adjust power in a certain range to ensure the consistency of the cutting effect;
– Automatic recognition: Neutral unipolar/bipolar plate automatic recognition, when using the dual-circuit plates and the contact area less than 60%, it should automatically stop the power output and send sound-light alarm until the contact area returns to normal, which could effectively avoid burning patients by plates.