Compact 3-Channel Digital ECG Machine with Synchronous 12-Lead Acquisition, High-Resolution Thermal Printing, Automatic Rhythm Interpretation, and Retractable Carry Handle
-
ECG machine manufacturer China, OEM 3-channel EKG factory, ISO 13485 certified electrocardiograph supplier, wholesale portable cardiology equipment.
-
3 channel ECG machine with auto interpretation, portable EKG with retractable handle, resting 12 lead ECG with thermal printer, CE certified clinic ECG
Quick Info.
- SKU NO.: UMH-3303G
- Device Classification: Class Ⅱ
- Warranty: 1 Year
- Power Source: Electric
- Transport Package: Carton or Wooden Cases
- Origin: China
- Material: Metal, Plastic
- After-Sale Service: Online Technical Support
- Production Capacity: 500 Sets/Year
Reliable 12-Lead Electrocardiography for Decentralized Clinical Care
Outpatient primary clinics, emergency triage stations, and mobile medical teams require electrocardiography instruments that provide uncompromising trace clarity without complicated setups. This compact 3-channel digital ECG machine delivers synchronous 12-lead acquisition with gold-standard signal-to-noise performance. Driven by high-precision analog-to-digital processing and adaptive digital filtering, the system eliminates baseline drift and muscle tremors, providing cardiologists with pristine P-QRS-T complexes for evaluating ischemic coronary conditions and arrhythmias.
Automated Interpretation with Integrated High-Definition Thermal Printing
Accelerate diagnostic workflows during critical patient checkups. Equipped with an internal thermal line printer, the device outputs high-contrast 3-channel waveforms directly onto standard grid paper, accompanied by an automated analytical report that measures ventricular rates, PR intervals, and axis variations. Technicians can preview live traces on the color LCD display and freeze waveforms to catch transient ectopic beats before committing them to paper, significantly reducing clinical paper waste and speeding turnaround times.
Rugged Field Portability and Hospital-Wide Network Integration
Built for demanding daily duty cycles, the machine features a sealed membrane console that resists sanitizing wipes, alongside an integrated retractable handle for rapid room-to-room transport. The rear and side interface panel includes USB and Ethernet ports, allowing clinical teams to archive patient cases as universal PDF files or transmit raw examination records to hospital cardiology PACS through standard DICOM 3.0 protocols. Fully certified under ISO 13485 and CE medical directives, this unit serves as a turn-key diagnostic asset for overseas distribution networks.
The Specific Parameters

-
Synchronous 12-Lead Precision Acquisition: Captures standard 12-lead cardiac potentials simultaneously with low noise baseline stability, advanced 24-bit A/D conversion, and high common mode rejection ratio (> 100 dB).
-
Built-In High-Resolution Thermal Recorder: Equipped with a precision linear array thermal print engine, delivering crisp 3-channel real-time waveforms, rhythm leads, and clinical parameter reports on standard thermal paper.
-
Comprehensive Automated Diagnostic Algorithm: Automatically calculates essential clinical intervals (Heart Rate, PR interval, QRS duration, QT/QTc, P/QRS/T electrical axes) and outputs diagnostic interpretation summaries to speed up emergency evaluations.
-
Advanced Multi-Tier Digital Filtering: Integrates selectable AC, EMG, and baseline wander (ADS) filters to eliminate ambient baseline artifacts during mobile outpatient and ambulance applications.
-
Ergonomic Retractable Briefcase Mobility: Features a flush-folding top carrying handle, spill-resistant membrane tactile keys, and dual AC/DC power operation with an internal rechargeable lithium battery providing up to 4 hours of continuous fieldwork.
🏥Technical Specifications
| Item | Specification | Item | Specification |
|---|---|---|---|
| Lead | Standard 12 leads | Time constant | ≥3.2s |
| Lead acquisition | 12 leads synchronously acquisition | Frequency response | 0.05~160Hz (-3db) |
| Work mode | Manual / Auto / R-R / Store | Noise level | <15μVp-p |
| Filter | AC Filter: 50Hz / 60Hz
EMG Filter: 25Hz / 45Hz Anti-Drift Filter: 0.15Hz (adaptive ) |
Inter-channel interference | ≤0.5mm |
| CMRR | ≥120dB ( with AC Filter ) | Sensitivity | Auto, 2.5, 5, 10, 20, 40mm/mV (±3%) |
| Input circuit | Floating ; Protection circuit against defibrillator effect | Recording mode | 1ch+, 3ch, 3ch+ |
| Input impedance | ≥50MΩ | Paper speed | 6.25, 12.5, 25, 50mm/s (±3%) |
| Input circuit current | ≤0.05μA | Recording Paper | 80mmx20m roll paper |
| Patient current leakage | <10μA | Working environment | Temperature 5-40 C; Humidity 25-95% |
| Calibrating voltage | 1mV ±2% | Power supply | AC 110-230V (±10%), 50/60Hz (±1Hz)
DC Built-in rechargeable Li-ion battery, 14.4V, 2200mAh |
| Voltage tolerance | ≥ ±500mV | Communication Port | USB, UART |
| Dimension / Weight | 300mmx230mmx72mm, 2.8kgs. |
Q: What is the clinical benefit of synchronous 12-lead acquisition on a 3-channel ECG machine?
A: Synchronous 12-lead acquisition captures electrical signals from all twelve cardiac vectors simultaneously, rather than sequentially. This eliminates temporal phase errors, ensuring that arrhythmias, ectopic beats, and ST-segment elevations are correlated across all leads at the exact same moment in time.
Q: What paper format does the built-in thermal recorder use?
A: The integrated thermal recorder utilizes standard 80 mm width thermal recording paper rolls or Z-fold paper. It outputs three channels of diagnostic waveforms alongside printed patient demographics, sensitivity settings, and automated clinical measurements.
Q: Does the unit feature automatic interpretation of ECG anomalies?
A: Yes. The device integrates an automatic interpretation program that measures heart rate, PR interval, QRS duration, QT/QTc intervals, and frontal plane electrical axes, providing an immediate diagnostic summary note on both the screen and printed reports.
Q: Can this electrocardiograph store patient files digitally and export them to a PC?
A: Yes. The unit features built-in flash memory capable of archiving over 1,000 patient examinations. Technicians can export records as PDF, XML, or image files onto standard USB flash drives, or transfer raw data via the RJ45 network port to hospital electronic medical records (EMR) and PACS.
Q: What OEM private-label customization options are provided for overseas distributors?
A: Complete factory-direct OEM support includes customized keyboard membrane labeling, multi-language system software (English, Spanish, French, Russian, German, Portuguese), custom client branding on the exterior chassis, localized power cords, and full CE/ISO 13485 technical regulatory documentation.